dc.contributor.supervisor Dick, Kristopher (Biosystems Engineering) en_US
dc.contributor.author Orchard, David
dc.date.accessioned 2012-01-17T00:23:26Z
dc.date.available 2012-01-17T00:23:26Z
dc.date.issued 2012-01-16
dc.identifier.uri http://hdl.handle.net/1993/5099
dc.description.abstract In 2004 a post-frame structure with plastered straw bales as an in-fill wall system was built at the University of Manitoba. Load cells installed at the top and bottom of ten eave wall posts were intended to measure the tributary load transferred from the roof structure into the supporting posts. In 2011 wind speed and direction were measured adjacent to the structure and correlated to simultaneous load data. A linear regression model relating load to wind speed within four directional quadrants revealed that load behaviour was inconsistent with design-level loading prescribed by the National Building Code of Canada (2005). A second regression model with both speed and direction as independent variables did not determine any statistically significant relationships. This research concluded that the initial assumptions made in 2004 required additional scrutiny, including the conditions under which the load cells were calibrated, and the structural contribution of the walls’ plastered skins. en_US
dc.rights info:eu-repo/semantics/openAccess
dc.subject post-frame en_US
dc.subject wind load en_US
dc.title Correlation of roof loads to wind speed and direction on a post-frame building in real time en_US
dc.type info:eu-repo/semantics/masterThesis
dc.type master thesis en_US
dc.degree.discipline Biosystems Engineering en_US
dc.contributor.examiningcommittee Britton, Ron (Biosystems Engineering) Blatz, James (Civil Engineering) en_US
dc.degree.level Master of Science (M.Sc.) en_US
dc.description.note February 2012 en_US