Seismic performance of circular columns rehabilitated with sprayed-GFRP composites

Loading...
Thumbnail Image
Date
2018
Authors
Mohit, Syed Abdullah
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
This study investigates the seismic behaviour of RC circular columns rehabilitated using sprayed-glass fibre reinforced polymer (sprayed-GFRP) composites. Six large-scale RC circular columns were constructed and tested under reversal-cyclic load and constant axial load (equal to 20% of column axial load capacity). All specimens were deficient in lap splice length and had a diameter of 305-mm with 1,525-mm shear span (length). A 3.0-mm and 6.0-mm thick sprayed-GFRP coating was used for rehabilitation. Two specimens were strengthened without prior loading, two specimens were rehabilitated after being partially damaged (up to 2.5% drift ratio) and two specimens were rehabilitated after being fully-damaged. Sprayed-GFRP of 3-mm thickness is inadequate for rehabilitation of the fully damaged column. However, it can be used for strengthening and rehabilitation of partially-damaged columns. Sprayed-GFRP of 6-mm thickness not only increased the drift capacity of the column but also successfully restored the full capacity of seismically damaged RC columns.
Description
Keywords
Seismic load, Circular columns, Rehabilitation, Sprayed-GFRP composites