dc.description.abstractScattered coincidences degrade image contrast and compromise quantitative accuracy in positron emission tomography (PET). A number of approaches to estimating and correcting scattered coincidences have been proposed, but most of them are based on estimating and subtracting a scatter sinogram from the measured data. We have previously shown that both true and scattered coincidences can be treated similarly by using Compton scattering kinematics to define a locus of scattering which may in turn be used to reconstruct the activity distribution using a generalized scatter maximum-likelihood expectation maximization (GS-MLEM) algorithm. The annihilation position can be further confined by taking advantage of the patient outline (or a geometrical shape that encompasses the patient outline). The proposed method was tested on a phantom generated using GATE. The results have shown that for scatter fractions of 10–60% this algorithm improves the contrast recovery coefficients (CRC) by 4 to 28.6% for a source and 5.1 to 40% for a cold source while the relative standard deviation (RSD) was reduced. Including scattered photons directly into the reconstruction eliminates the need for (often empirical) scatter corrections, and further improvements in the contrast and noise properties of the reconstructed images can be made by including the patient outline in the reconstruction algorithm as a constraint.
dc.description.versionPeer Reviewed
dc.identifier.citationHongyan Sun and Stephen Pistorius, “Evaluation of Image Quality Improvements When Adding Patient Outline Constraints into a Generalized Scatter PET Reconstruction Algorithm,” ISRN Biomedical Imaging, vol. 2013, Article ID 326847, 8 pages, 2013. doi:10.1155/2013/326847
dc.identifier.urihttp://dx.doi.org/10.1155/2013/326847
dc.identifier.urihttp://hdl.handle.net/1993/30478
dc.language.rfc3066en
dc.rightsopen accessen_US
dc.rights.holderCopyright © 2013 Hongyan Sun and Stephen Pistorius. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
dc.titleEvaluation of Image Quality Improvements When Adding Patient Outline Constraints into a Generalized Scatter PET Reconstruction Algorithm
dc.typeJournal Article
Files
Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
2020.2013.326847.xml
Size:
7.42 KB
Format:
Extensible Markup Language
Description:
Loading...
Thumbnail Image
Name:
2020.2013.326847.pdf
Size:
1.59 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.27 KB
Format:
Item-specific license agreed to upon submission
Description: