Investigation of Advanced Dose Verification Techniques for External Beam Radiation Treatment

dc.contributor.authorAsuni, Ganiyu
dc.contributor.examiningcommitteeBews, Jeffrey (Physics and Astronomy) Gericke, Micheal (Physics and Astronomy) Venkataraman, Sankar (Physics and Astronomy) Thomas, Gabriel (Electrical and Computer Engineering) Jirasek, Andrew (University of Victoria)en_US
dc.contributor.supervisorMcCurdy, Boyd (Physics and Astronomy)en_US
dc.date.accessioned2013-07-08T14:12:04Z
dc.date.available2013-07-08T14:12:04Z
dc.date.issued2012en_US
dc.degree.disciplinePhysics and Astronomyen_US
dc.degree.levelDoctor of Philosophy (Ph.D.)en_US
dc.description.abstractIntensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) have been introduced in radiation therapy to achieve highly conformal dose distributions around the tumour while minimizing dose to surrounding normal tissues. These techniques have increased the need for comprehensive quality assurance tests, to verify that customized patient treatment plans are accurately delivered during treatment. In vivo dose verification, performed during treatment delivery, confirms that the actual dose delivered is the same as the prescribed dose, helping to reduce treatment delivery errors. In vivo measurements may be accomplished using entrance or exit detectors. The objective of this project is to investigate a novel entrance detector designed for in vivo dose verification. This thesis is separated into three main investigations, focusing on a prototype entrance transmission detector (TRD) developed by IBA Dosimetry, Germany. First contaminant electrons generated by the TRD in a 6 MV photon beam were investigated using Monte Carlo (MC) simulation. This study demonstrates that modification of the contaminant electron model in the treatment planning system is required for accurate patient dose calculation in buildup regions when using the device. Second, the ability of the TRD to accurately measure dose from IMRT and VMAT was investigated by characterising the spatial resolution of the device. This was accomplished by measuring the point spread function with further validation provided by MC simulation. Comparisons of measured and calculated doses show that the spatial resolution of the TRD allows for measurement of clinical IMRT fields within acceptable tolerance. Finally, a new general research tool was developed to perform MC simulations for VMAT and IMRT treatments, simultaneously tracking dose deposition in both the patient CT geometry and an arbitrary planar detector system, generalized to handle either entrance or exit orientations. It was demonstrated that the tool accurately simulates dose to the patient CT and planar detector geometries. The tool has been made freely available to the medical physics research community to help advance the development of in vivo planar detectors. In conclusion, this thesis presents several investigations that improve the understanding of a novel entrance detector designed for patient in vivo dosimetry.en_US
dc.description.noteOctober 2013en_US
dc.identifier.citationMed. Phys. 39, 697 - 705 (2012)en_US
dc.identifier.urihttp://hdl.handle.net/1993/21706
dc.language.isoengen_US
dc.publisherMedical Physicsen_US
dc.rightsopen accessen_US
dc.subjectDose verificationen_US
dc.subjectRadiation dosimetryen_US
dc.subjectMonte Carloen_US
dc.subjectTransmission detectoren_US
dc.subjectElectronic portal imaging deviceen_US
dc.subjectSpatial resolutionen_US
dc.subjectContaminant electronsen_US
dc.titleInvestigation of Advanced Dose Verification Techniques for External Beam Radiation Treatmenten_US
dc.typedoctoral thesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Ganiyu_Asuni.pdf
Size:
2.25 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.25 KB
Format:
Item-specific license agreed to upon submission
Description: