An algorithm for the simultaneous reconstruction of the radionuclide activity distribution and attenuation map based on PET scatter data

dc.contributor.authorZhang, Geng
dc.contributor.examiningcommitteeGoertzen, Andrew (Physics and Astronomy) Wang, Yang (Computer Science)en_US
dc.contributor.supervisorPistorius, Stephen (Physics and Astronomy)en_US
dc.date.accessioned2015-09-14T20:24:24Z
dc.date.available2015-09-14T20:24:24Z
dc.date.issued2015
dc.degree.disciplinePhysics and Astronomyen_US
dc.degree.levelMaster of Science (M.Sc.)en_US
dc.description.abstractAttenuation correction is required for both qualitative and quantitative analysis of positron emission tomography (PET) imaging. Traditional attenuation correction methods use a transmission scan, such as a computerized tomography (CT) or an external radionuclide source scan. The transmission scan contaminates the emission data of PET if the transmission scan is performed during the PET scan. When the transmission scan is performed separately, artifacts can be introduced due to patient movement. In addition, the conversion of the CT image to an attenuation map at PET energy and the smaller field-of-view (FOV) of a transmission scan cause other artifacts. For PET/MR systems, detector compatibility issues for traditional PET scanners along with image truncation and patient movements also introduce artifacts. Therefore a transmission-less attenuation correction approach is needed. Previous studies using true coincidence data to simultaneously reconstruct the attenuation map and radionuclide activity distribution suffer from the cross-talk between the distributions. In this study, the scatter data of PET was used to reconstruct the electron density distribution as a representation of the attenuation map. A simultaneous reconstruction of the activity and electron density distributions were developed. Reconstruction results have shown that the contrast recovery coefficients of the region of interests were comparable to the reconstructions using a known attenuation map.en_US
dc.description.noteOctober 2015en_US
dc.identifier.urihttp://hdl.handle.net/1993/30803
dc.language.isoengen_US
dc.rightsopen accessen_US
dc.subjectPET, Scatter, Attenuation correction, Electron density, Simultaneous Reconstruction.en_US
dc.titleAn algorithm for the simultaneous reconstruction of the radionuclide activity distribution and attenuation map based on PET scatter dataen_US
dc.typemaster thesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Zhang_Geng.pdf
Size:
3.75 MB
Format:
Adobe Portable Document Format
Description:
Thesis of MSc
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.25 KB
Format:
Item-specific license agreed to upon submission
Description: