Evaluation of partial discharge characteristics in inclined plane tracking and erosion tests on silicone rubber under AC and DC voltages

dc.contributor.authorPevtsov, Valeria
dc.contributor.examiningcommitteeFilizadeh, Shaahin (Electrical and Computer Engineering) Fernando, Namal (Electrical and Computer Engineering) Jacob, Nathan (Manitoba Hydro)en_US
dc.contributor.supervisorKordi, Behzad (Electrical and Computer Engineering)en_US
dc.date.accessioned2021-01-12T23:01:44Z
dc.date.available2021-01-12T23:01:44Z
dc.date.copyright2020-12-21
dc.date.issued2020en_US
dc.date.submitted2020-12-22T03:27:50Zen_US
dc.degree.disciplineElectrical and Computer Engineeringen_US
dc.degree.levelMaster of Science (M.Sc.)en_US
dc.description.abstractPolymer housing material for transmission line insulators offers superior pollution performance compared to glass and ceramic. However, in coastal and high pollution environments polymer insulators are susceptible to accelerated aging caused by electrical tracking and erosion. In the last couple of decades, field and laboratory studies on polymeric insulators have shown that tracking and erosion are more severe for outdoor insulation under DC voltage stress compared to AC stress at similar voltage magnitudes. Therefore, with the increased development in DC mode of power delivery, design of erosion resistant materials to improve the reliability of DC insulation systems has become an important task. This task relies on a thorough understanding of the mechanisms that lead to material erosion. This thesis investigates partial discharge (PD) characteristics of discharges that lead to erosion of silicone rubber (SR) polymer under AC stress and DC stress of both polarities. The experiments are performed on high temperature vulcanized SR material samples. The inclined plane test apparatus, constructed in accordance with IEC 60587 requirements, is employed to produce the surface partial discharges and the resulting accelerated aging of the specimens. Two commercial instruments are used to obtain PD data. A concurrent analysis of visual observations of discharge and partial discharge data is performed to classify discharges based on the severity of material degradation that each type causes. PD characteristics were identified for three types of discharges, using phase resolved PD patterns, PD histograms, and a signal processing technique called Time Frequency mapping. Individual pulse waveshapes of each type of discharge were also analyzed. Amplitude, energy, pulse width, and frequency spectrum were evaluated and compared for the eroding discharge pulses at the three voltage types. It was concluded that greater pulse width and the presence of dominant DC component in the spectrum are attributable to discharges that cause greater severity of SR erosion under DC stress relative to AC.en_US
dc.description.noteFebruary 2021en_US
dc.identifier.citationV. Pevtsov, N. Jacob, and B. Kordi, “Evaluation of partial discharge characteristics in inclined plane tracking and erosion tests on silicone rubber under ac voltage,” in 2020 IEEE Electrical Insulation Conference (EIC), 2020, pp. 175–178en_US
dc.identifier.urihttp://hdl.handle.net/1993/35219
dc.language.isoengen_US
dc.rightsopen accessen_US
dc.subjectTracking, Erosion, Partial discharge, Inclined plane, Polymer, Insulatoren_US
dc.titleEvaluation of partial discharge characteristics in inclined plane tracking and erosion tests on silicone rubber under AC and DC voltagesen_US
dc.typemaster thesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Pevtsov_Valeria.pdf
Size:
11.46 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.2 KB
Format:
Item-specific license agreed to upon submission
Description: