Validity and feasibility of a tri-axial accelerometer for measuring an upper limb Fitts’ Task

dc.contributor.authorMalone, Quinn
dc.contributor.examiningcommitteeSinger, Jonathan (Kinesiology and Recreation Management) MacNeil, Brian (Rehabilitation Sciences)en_US
dc.contributor.supervisorPassmore, Steven (Kinesiology and Recreation Management)en_US
dc.date.accessioned2021-08-04T18:01:26Z
dc.date.available2021-08-04T18:01:26Z
dc.date.copyright2021-07-28
dc.date.issued2021-07en_US
dc.date.submitted2021-07-28T20:59:10Zen_US
dc.date.submitted2021-08-04T17:48:51Zen_US
dc.degree.disciplineKinesiology and Recreation Managementen_US
dc.degree.levelMaster of Science (M.Sc.)en_US
dc.description.abstractBackground: Devices used to display and record Fitts’ task performance typically lack portability and accessibility outside the laboratory environment. Touch-based interfaces, while more portable, cannot yield many secondary measures of interest. A portable acceleration- and touch-based equipment package was developed to facilitate the application of the Fitts’ task in remote environments. Purpose: To validate a novel portable acceleration and touch-based hardware and software package which can assess both primary and secondary Fitts’ task performance measures. Methods: Participants (N=22) set up the equipment and tested themselves remotely with live video support. Protocols from Glazebrook et al. (2015), which measured a violation of Fitts’ Law using gold-standard equipment, were replicated. Groups of three closely spaced target placeholders were displayed. Participants touched the one filled-in target placeholder. Two measurement methods, touch and acceleration, were compared using linear regressions performed on movement onset and movement offset. Statistical results from both measurement methods were compared categorically to results from Glazebrook et al. (2015). Results: The findings of Glazebrook et al (2015) were replicated using the novel portable acceleration and touch-based equipment. The touch and acceleration methods of measuring movement onset and offset were significantly correlated (p<0.001). Conclusions: A portable acceleration method of measuring the Fitts’ task was validated as: 1) it provided similar results to a touch-based method, but with richer secondary data; and 2) it replicated the findings of Glazebrook et al. (2015), which used gold-standard equipment. An alternate hypothesis concerning the cause of the violation of Fitts’ Law is discussed.en_US
dc.description.noteOctober 2021en_US
dc.identifier.urihttp://hdl.handle.net/1993/35781
dc.language.isoengen_US
dc.rightsopen accessen_US
dc.subjectFitts' Law; Fitts's Law; Kinematic analysis; Manual aiming; Reaching; Feasibility; Validity; Electronics; Wearable; Healthcare; Toolen_US
dc.titleValidity and feasibility of a tri-axial accelerometer for measuring an upper limb Fitts’ Tasken_US
dc.typemaster thesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Quinn_Malone.pdf
Size:
2.03 MB
Format:
Adobe Portable Document Format
Description:
Main article
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.2 KB
Format:
Item-specific license agreed to upon submission
Description: