dc.description.abstractToday’s clinical magnetic resonance imaging (MRI) systems have B0-fields of 1.5 − 7.0T, and research usage time on these high-field systems is limited and expensive. The development of novel MRI techniques, such as transmit array spatial encoding (TRASE), can be accelerated by access to in-house, small-scale, low-field systems. This thesis therefore develops a method for designing a low-field magnet with excellent field homogeneity. The value of this method is its versatility: while it is used here to design a uniform field within a cylindrical volume, the method can also be applied to other geometries and to produce any desired field profile. An overview of the design method, and the research performed in this thesis, is as follows. The magnetic scalar potential Φ is chosen inside what will be the magnet volume to give the desired field profile; outside, however, an outer boundary surface is set-up and Φ is solved for numerically from the Laplace equation using a finite element method within the region between the two surfaces. The discontinuity in the magnetic scalar potential ∆Φ at the surface of the inner volume gives the required surface current distribution of the magnet, which is then discretized into wires. Biot-Savart field calculations are used to simulate the field and quantify its homogeneity. The cylindrical magnet of 25-cm radius and 1-m length designed here is found to have a theoretical homogeneity of < 1 ppm over a 20-cm diameter spherical volume.en_US
dc.description.noteMay 2019en_US
dc.identifier.urihttp://hdl.handle.net/1993/33765
dc.language.isoengen_US
dc.rightsopen accessen_US
dc.subjectMagnetic Resonanceen_US
dc.subjectTransmit Array Spatial Encoding (TRASE) MRIen_US
dc.subjectMagnet designen_US
dc.subjectLow fielden_US
dc.titleA homogeneous RF-shielded magnet for low-field magnetic resonance studiesen_US
dc.typemaster thesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Smith_Kyla.pdf
Size:
13.16 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.2 KB
Format:
Item-specific license agreed to upon submission
Description: