Towards the development of a mixed reality haptic temporal bone surgical simulation

dc.contributor.authorRampersad, Vivek
dc.contributor.examiningcommitteeBalakrishnan, Subramaniam (Mechanical Engineering) Kinsner, Witold (Electrical and Computer Engineering)en_US
dc.contributor.supervisorSepehri, Nariman (Mechanical Engineering) Unger, Bertram (Mechanical Engineering)en_US
dc.date.accessioned2016-01-12T14:21:12Z
dc.date.available2016-01-12T14:21:12Z
dc.date.issued2015
dc.degree.disciplineMechanical Engineeringen_US
dc.degree.levelMaster of Science (M.Sc.)en_US
dc.description.abstractThe temporal bone is an anatomically complex region within the skull. Current training for temporal bone surgery includes cadaveric, physical and virtual haptic simulations and apprenticeships. Cadavers are limited by low supply. Haptic devices are limited by their force and stiffness ratings and thus cannot adequately simulate rigid materials. Physical simulations excel at simulating stiff materials but do a poor job of soft tissue. The research objective was to develop a mixed reality (MR) temporal bone surgical haptic simulation. This novel concept would utilize physical models to simulate bone and haptic forces to simulate soft tissue. A surgical drill was attached to a Quanser® High Definition Haptic DeviceTM (HD2) via a clamp. An algorithm was implemented to simulate a force at the drill tip and to negate the weight of the clamp. This modified haptic system was interfaced to a temporal bone haptic simulation. Haptic chatter unique to the modified haptic system was observed and low-pass filters were used to mitigate this issue. Due to the poor positional accuracy of the HD2, MR simulation was not achieved. However, VR haptic simulation was achieved. Six expert surgeons were recruited to investigate the following questions: "What is the impact of different haptic hardware on surgical realism?" and "Would end users prefer a surgical drill over a standard haptic manipulandum?" Three cases were compared: a Phantom Omni®, a standard HD2 and a modified HD2 with attached drill. Expert surgeons rated the standard HD2 and Phantom Omni equivalently whilst preferring the modified HD2 with attached drill. Though the modified HD2 scored higher in all categories only “Acoustics” and “Overall Appreciation” displayed statistical significance. This implies that drill acoustics is critical for realism.en_US
dc.description.noteFebruary 2016en_US
dc.identifier.urihttp://hdl.handle.net/1993/31029
dc.language.isoengen_US
dc.rightsopen accessen_US
dc.subjectHapticsen_US
dc.subjectMixed realityen_US
dc.subjectTemporal boneen_US
dc.subjectSurgical simulationen_US
dc.titleTowards the development of a mixed reality haptic temporal bone surgical simulationen_US
dc.typemaster thesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Rampersad_Vivek.pdf
Size:
3.51 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.16 KB
Format:
Item-specific license agreed to upon submission
Description: