Comparison of Cyanoacrylate Tissue Adhesives to Polytetrafluoroethylene Sutures in the Donor Site of Connective Tissue Grafts – A Randomized Clinical Trial

dc.contributor.authorStavropoulou, Chrysi
dc.date.accessioned2018-07-18T21:23:58Z
dc.date.available2018-07-18T21:23:58Z
dc.date.issued2018-06
dc.date.submitted2018-07-18T21:23:58Zen
dc.description.abstractPurpose: The aim of this study was to compare patient-centered outcomes, wound healing and post-operative complications at palatal donor area of SECT grafts between cyanoacrylates tissue adhesives and Polytetrafluoroethylene (PTFE) sutures. Methods: 36 patients who required harvesting of SECT graft were enrolled in this prospective randomized clinical trial and assigned to one of two groups. In the “suture” group, wound closure was achieved with standardized continuous interlocking 6-0 PTFE sutures, while in the “cyanoacrylate” group, a high viscosity blend of n-butyl and 2-octyl cyanoacrylate was applied until hemostasis was achieved. The primary outcome was the discomfort (eating, speaking etc) from the donor site during the first post-operative week; this was self-reported on a visual analogue scale (VAS) questionnaire. Secondary outcomes were the time required for suture placement or cyanoacrylate application, the patient self-reported pain on the first day, and the first week after surgery, the analgesic-intake and the modified early-wound healing index (MEHI). Results: The median value of discomfort was 1.49 cm in the “suture” group and 1.86 cm in the “cyanoacrylate” (p=0.56). The mean time required for suture placement was 7.31 minutes and for cyanoacrylate application 2.16 minutes (p<0.0001). No statistically significant differences were found between the two methods in reported level of pain, in analgesic intake and in MEHI. Conclusion: Cyanoacrylate can safely be used for wound closure of donor palatal site of SCTG. The application was about 5 minutes faster than conventional suture placement, reducing the total time of the surgical procedure.en_US
dc.identifier.urihttp://hdl.handle.net/1993/33177
dc.language.isoengen_US
dc.rightsopen accessen_US
dc.subjectcyanoacrylatesen_US
dc.subjectsuturesen_US
dc.subjectwound healingen_US
dc.subjecttissue graftsen_US
dc.subjectclinical trialen_US
dc.titleComparison of Cyanoacrylate Tissue Adhesives to Polytetrafluoroethylene Sutures in the Donor Site of Connective Tissue Grafts – A Randomized Clinical Trialen_US
dc.typebachelor thesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Stavropoulou MDent Thesis.pdf
Size:
722.8 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: