    Fault detection and fault-tolerant control of single-rod electrohydrostatic actuated system

    Thumbnail
    View/Open
    Thesis-Amirreza-Final.pdf (5.431Mb)
    Date
    2021-08
    Author
    Mirbeygi Moghaddam, Amirreza
    Metadata
    Show full item record
    Abstract
    Single-rod electrohydrostatic actuators present an efficient alternative to valve-controlled systems. However, such systems have significant nonlinearities and as is the case with hydraulic circuits, the possibility of faults exists in the system. Since these faults cannot be seen directly and have significant effects on the overall behaviour of the Electrohydrostatic Actuator (EHA), it is of crucial importance that they are detected and the performance of the EHA is restored. These behavioural complexities along with its asymmetrical dynamics, make the control task of the single-rod EHA challenging. In this thesis, by acquiring accurate signals from a single-rod EHA using a novel fuzzy denoising method a fault detection analysis is performed in a multi-fault environment. To do so Variance Fractal Dimension (VFD), Length Fractal Dimension (LFD) and wavelet detail coefficients are utilized. Also, the severity of the faults (bulk modulus and internal leakage) is associated with the aforementioned measures. Building upon this comprehensive analysis, a fault decision algorithm is developed to allocate a quantitative value to the internal leakage severity in the system if such fault occurs. With regards to control, first, a healthy condition and a faulty condition Fractional-Order Proportional Integral Derivative (FOPID) controller are developed and optimized using the Modified Nelder-Mead (MNM) algorithm. Using these two FOPID controllers, then, the fault-tolerant controller is designed which uses the generated degree of fault variable from the fault detection algorithm to assign a weight to each of the inputs from the two controllers through a fuzzy inference system. The effectiveness of the fault detection and control strategies is demonstrated in several experimental results.
    URI
    http://hdl.handle.net/1993/35816
    Collections
    • FGS - Electronic Theses and Practica [25529]

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of MSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV