• Libraries
    • Log in to:
    View Item 
    •   MSpace Home
    • Faculty of Graduate Studies (Electronic Theses and Practica)
    • FGS - Electronic Theses and Practica
    • View Item
    •   MSpace Home
    • Faculty of Graduate Studies (Electronic Theses and Practica)
    • FGS - Electronic Theses and Practica
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Probing tissue microstructure using oscillating spin echo gradients

    Thumbnail
    View/Open
    mercredi_morgan.pdf (3.082Mb)
    Date
    2018
    Author
    Mercredi, Morgan Elias
    Metadata
    Show full item record
    Abstract
    The central nervous system (CNS) is made up of neurons and glial cells. Information is transmitted along axons to other neurons, muscles, or glands. Recent studies indicate possible changes in axon diameter distributions associated with diseases such as Alzheimer’s disease, autism, dyslexia, and schizophrenia. Magnetic resonance imaging (MRI) techniques such as diffusion MRI can be used to probe the tissue microstructure of the brain noninvasively. Current MRI axon diameter measurements rely on the pulsed gradient spin echo sequence which cannot provide short enough diffusion times to measure small axon diameters. Recent advances have allowed oscillating gradient (OG) diffusion MRI to infer the sizes of micron-scale axon diameters. Monte Carlo simulations of cosine OG sequences were conducted on a parallel cylinder (diameters 1 to 10 µm) geometry. For feasible experiments on a Bruker BG6 gradient set, the simulations inferred diameters as small as 1 µm on square packed and randomly packed cylinders. The accuracy of the inferred diameters was found to be dependent on the signal-to-noise ratio (SNR) with smaller diameters more affected by noise although all diameter distributions were distinguishable from one another for all SNRs tested. Five frequencies were adequate for d = 3 – 5 µm with single-sized cylinders and for effective mean axon diameters (AxD) greater than 2 µm for cylinders with a distributions of diameters. There was some improvement in precision for d = 1 – 2 µm with 10 frequencies. It was better to repeat measurements at higher gradient strengths than to use a range of gradient strengths. Data were collected from a portion of normal-appearing corpus callosum from an autopsy human brain, which did not demonstrate any pathological changes. The average fitted AxD was 2.0 ± 0.2 µm, while AxD obtained from electron microscopy was 1.4 ± 0.2 µm. Fitted AxD showed more variability below 7 OG frequencies and little change when using two or three gradient strengths, agreeing with the simulations.
    URI
    http://hdl.handle.net/1993/33314
    Collections
    • FGS - Electronic Theses and Practica [25525]

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of MSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV