The role of tissue Doppler imaging using transesophageal echocardiography in the non-invasive assessment of left ventricular filling pressures during cardiac surgery

dc.contributor.authorNepomuceno, Roman G.
dc.contributor.examiningcommitteeMedicineen_US
dc.contributor.supervisorDr. Davinder S. Jassal (Internal Medicine) and Dr. Scott Mackenzie (Anesthesia).en_US
dc.date.accessioned2012-03-12T19:42:27Z
dc.date.available2012-03-12T19:42:27Z
dc.date.issued2012-03-12
dc.degree.disciplineMedicineen_US
dc.degree.levelBachelor of Science (B.Sc.)en_US
dc.description.abstractBackground: Cardiac surgical patients often require invasive pulmonary artery catheters (PAC) to determine left ventricular filling pressures (LVFP) in order to guide fluid management. Tissue Doppler imaging (TDI) as derived by transthoracic echocardiography (TTE), non-invasively assesses pulmonary capillary wedge pressure (PCWP), which is a surrogate for LVFP. With the use of TDI as derived by TTE, the ratio of transmitral inflow to mitral annular velocity during early diastole (E/E’) correlates with PCWP. However, little is known on the role of TDI using intra-operative transesophageal echocardiography (TEE) in the assessment of LVFP during cardiac surgery. Objective: To determine if TDI indices obtained by intra-operative TEE during cardiac surgery accurately estimates PCWP using PAC as the gold standard. Methods: Patients undergoing cardiac surgery were prospectively enrolled at a single tertiary care centre. Conventional and novel echocardiographic parameters were evaluated using intra-operative TEE with concurrent invasive PAC monitoring before and after cardiopulmonary bypass (CPB). Results: The study population included 34 patients (26 males, mean age 649 years). The correlation between E/E’ using TEE and PCWP was poor to modest at best. Pre-CPB, the correlation ratio between mean E/E’ and PCWP was r=0.23. Post-CPB, the correlation ratio between mean E/E’ and PCWP was r=0.42. Conclusion: Intra-operative TEE was unable to accurately assess LVFP in patients undergoing cardiac surgery. The PAC continues to be the gold standard in the assessment of LVFP for this patient population.en_US
dc.description.noteOctober 2011en_US
dc.identifier.urihttp://hdl.handle.net/1993/5181
dc.rightsopen accessen_US
dc.subjectmedicineen_US
dc.titleThe role of tissue Doppler imaging using transesophageal echocardiography in the non-invasive assessment of left ventricular filling pressures during cardiac surgeryen_US
dc.typebachelor thesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Nepomuceno_R_BScMed_2011.pdf
Size:
597.54 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: