    Adjustable anti-scatter grid system for mammography tomosynthesis final report

    Thumbnail
    View/Open
    13-Final Report.pdf (2.067Mb)
    Date
    2012-06-11
    Author
    Crawford, Graeme
    Dueck, Nathan
    Kirkbride-Taylor, Brian
    Bull, Jordan
    Metadata
    Show full item record
    Abstract
    Thirteen Engineering Co. (TEC) was tasked with developing a concept for an anti-scatter grid system that is compatible with mammography tomosynthesis machines, for CancerCare Manitoba (CCM). In the initial phases of the project, 16 concepts were generated. This was then narrowed down to the four most promising designs, from which two concepts were chosen to be developed further. The two designs chosen are the adjustable septa, and the multiple grid changer designs. In the adjustable septa concept the x-ray absorbing septa are redesigned so that they can be rotated. These septa can then be moved to the desirable angle for each image along the tomosynthesis sweep. The second concept is the multiple grid changer. In this design multiple anti-scatter grids with differing set septa angles are used. These grids are stored in a grid rack and then individually moved into the imaging position, as needed for the sweep. After an image is taken the anti-scatter grid is retracted and the next grid is then placed for imaging. To save space the grids are rotated halfway through an imaging sweep and then reused. In this report these two designs are developed further and their performance is compared against a previously selected set of criteria. It was found that the adjustable septa design had superior performance in the sweep angle, number of images per sweep, reliability and sweep completion time categories. The grid changer was better in the minimizing radiation dosage exposure category and both designs had a similar source to image distance. Due to the proprietary nature of tomosynthesis mammography machines, it was not possible to obtain dimensions for an existing device, because of this it was not possible to evaluate the designs based on device size. When both designs were compared to the project objectives, the adjustable septa design's performance exceeded the performance of the multiple grid changer design in many of the design criteria. TEC recommends the CCM should further develop the adjustable septa design. Further development in the areas of computer x-ray modelling and production of prototypes to properly establish the adjustable septa design's x-ray absorption properties, reliability, and manufacturing costs.
    URI
    http://hdl.handle.net/1993/7882
    Collections
    • Engineering Undergraduate Theses [192]

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of MSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV