Performance of GFRP headed-end bars as interface shear friction reinforcement

Loading...
Thumbnail Image

Authors

Ahmed, Mostafa

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

Many reinforced concrete (RC) structures rely on the transfer of shear forces across concrete interfaces, particularly in composite systems. A prime example is in bridge construction, where shear transfer between prestressed precast girder and cast-in-place slab is vital for composite action. While the interface shear transfer mechanism (IST) of steel-RC joints has been well-established and forms the basis of current design standards, limited research has explored the use of Glass Fibre-Reinforced Polymer (GFRP). As a corrosion-resistant, lightweight, and strong alternative in IST systems, GFRP offers promising potential for improving durability in harsh environments, enhancing shear transfer, and reducing maintenance costs.

This study explores the shear friction behaviour of composite RC elements using GFRP headed-end bars across various interface conditions, including cold joints (as-cast and roughened) and monolithic interfaces. A total of 28 large-scale push-off specimens were tested under monotonic axial loading to evaluate the influence of concrete strength (35 MPa and 55 MPa), reinforcement type (steel and GFRP), and reinforcement ratio (0.33, 0.43, 0.47, 0.66, and 1.00%) on IST performance. The GFRP shear connectors provided effective contribution to the shear transfer mechanism when adequate reinforcement ratios were provided in the cold joint condition, highlighting the importance of meeting the minimum reinforcement ratio required in current design provisions. When a reinforcement ratio of 0.33 % was employed, the peak load increased by a margin of 2-4% compared to the specimens without connectors. These increases were more pronounced when higher reinforcement ratios were utilized. GFRP-RC specimens exhibited post-cracking load recovery and higher residual capacities compared to steel-RC counterparts due to the linear-elastic behaviour, however, they displayed more brittle failure.

The test results showed that interface condition significantly influenced pre-cracking and post-cracking behaviour. As expected, monolithic specimens outperformed cold-joint ones, with up to 118% higher peak loads due to enhanced aggregate interlock., Surface roughening increased the capacity of GFRP-RC cold joint specimens by 2–23%, similar to those without shear connectors. Design model comparisons revealed that existing models in design provisions either significantly underestimate or overestimate the capacities of the tested specimens.

Description

Keywords

Cohesion, Cold joint, Composite construction, Glass fibre-reinforced polymer (GFRP), Headed-end bars, Interface shear transfer, Monolithic, Roughness, Shear friction

Citation