Transmission line protection in systems with high penetration of inverter-based resources (IBR)

dc.contributor.authorKapuge Kariyawasam Mudalige, Sachintha Kariyawasam
dc.contributor.examiningcommitteeGole, Aniruddha (Electrical and Computer Engineering)
dc.contributor.examiningcommitteePathirana, Vajira (Electrical and Computer Engineering)
dc.contributor.examiningcommitteeGokaraju, Ramakrishna (Electrical and Computer Engineering, University of Saskatchewan)
dc.contributor.supervisorRajapakse, Athula
dc.date.accessioned2026-11-03T19:33:23Z
dc.date.available2026-11-03T19:33:23Z
dc.date.issued2026-10-21
dc.date.submitted2026-10-21T23:36:33Zen_US
dc.degree.disciplineElectrical and Computer Engineering
dc.degree.levelDoctor of Philosophy (Ph.D.)
dc.description.abstractEver increasing integration of renewable resources into contemporary power systems has imposed a unique set of challenges for system protection. In the wake of several real-world incidents, effectiveness of techniques based on conventional system protection theory in protecting power systems with higher penetration of inverter-based resources (IBRs) has been under scrutiny. Faulted phase identification and fault direction identification are commonly affected protection functions in the presence of IBRs. Effects of IBRs on power swing characteristics also remain a largely unexplored topic. The work carried out in this Thesis firstly, investigates power system protection is-sues related to faulted phase identification and fault direction identification in systems with heavy IBR penetration and validates them using detailed simulations and testing of commercial protection relays. Secondly, this work attempts to overcome power system protection related challenges identified during initial investigations related to faulted phase identification and fault direction identification by developing new protection techniques. This work pro-poses a faulted phase identification method exploiting the relative strength of incremental voltages during faults, which is realized by specific processing of voltage measurements. In addition, this Thesis also presents a technique to correctly identify fault direction in transmission lines using negative-sequence admittance measurements. While both of the above-mentioned solutions are designed for systems with high IBR penetration, they have applicability in system with conventional power generation sources as well. Where applicable, the proposed protection methods have been grounded in and refined based on insights gained through theoretical analysis and, tested and validated using comprehensive Electromagnetic Transient (EMT) type simulation studies. Furthermore, this Thesis also investigates the effects of IBRs on the swing impedance trajectories during power swings by developing a theoretical model to incorporate IBRs into classical power swing analysis designed for synchronous machines. The proposed method of analysis provides a convenient way to integrate IBRs into out-of-step protection and relaying, which in turn improves design and performance of power system protection. The work carried out in this Thesis deepens the prevailing understanding of power system protection challenges caused by IBRs and proposes potential solutions for them, which have been validated by simulation studies to be reliable and robust.
dc.description.noteFebruary 2027
dc.identifier.urihttp://hdl.handle.net/1993/40199
dc.language.isoeng
dc.subjectPower System Protection
dc.titleTransmission line protection in systems with high penetration of inverter-based resources (IBR)
local.subject.manitobano

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Kapuge Kariyawasam Mudalige_Sachintha Kariyawasam.pdf
Size:
4.79 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.56 KB
Format:
Item-specific license agreed to upon submission
Description: