Investigation of the effects of humidity and surface charge on partial discharge in insulator posts under DC voltage

dc.contributor.authorDeng, Hao Liang
dc.contributor.examiningcommitteeRajapakse, Athula (Electrical and Computer Engineering) Fernando, Namal (Electrical and Computer Engineering)en_US
dc.contributor.supervisorKordi, Behzad (Electrical and Computer Engineering)en_US
dc.date.accessioned2020-03-12T14:58:46Z
dc.date.available2020-03-12T14:58:46Z
dc.date.copyright2020-03-11
dc.date.issued2020-03en_US
dc.date.submitted2020-03-11T17:47:32Zen_US
dc.degree.disciplineElectrical and Computer Engineeringen_US
dc.degree.levelMaster of Science (M.Sc.)en_US
dc.description.abstractThe flashover mechanism and performance of insulators have always been significant of importance to insulation engineers’ attention. A serious flashover accident will damage insulators and influence the reliability of the whole converter station and result in severe outages. It is believed that the flashover and partial discharge phenomena are strongly related to environmental conditions such as temperature, humidity, pressure, pollution's, and even space charges. The motivation of this thesis was to study the random discharge phenomenon that was observed in a Manitoba Hydro's HVDC substation to avoid further insulation damages. However, the lack of data prevents engineers from making firm conclusions. As such a data acquisition system was proposed that will collect leakage current data flowing in a reactor’s insulation post, to help to build a better understanding of the correlation between PD and environmental influences. The field tests at the HVDC substation studied the behavior of the leakage current from smoothing reactor’s ground wire and its associated electric field changes. Through the field tests, we found that the discharge phenomena exists only under certain weather conditions were. One hypothesis for partial discharge occurring on the insulator stacks is the influences of moisture and static charge. Moisture helps the static charge buildup on the insulator will spread along the insulator surface and create a conducting path between the smoothing reactor, flange, and ground. The sharp edge of the flange within this conducting path will generate corona and cause a discharge problem. For the laboratory experiments, humidity and surface charge studies were implemented in air and on FRP insulators under HVDC in order to get a better understanding of environmental influences on partial discharge behaviors. The results demonstrated that for a given electrode configuration, both humidity and surface charge have significant effects on the behavior of partial discharge. We also noticed that the relationship between total charge magnitude Q and equivalent frequency F followed a curve with exponential decay, and under high humidity environment or with surface charge present, the decay speed was faster than normal conditions. And the lab results also proved that time-frequency-charge (TFQ) mapping technique can be used for HVDC PD identifications.en_US
dc.description.noteMay 2020en_US
dc.identifier.citationIEEEen_US
dc.identifier.urihttp://hdl.handle.net/1993/34569
dc.language.isoengen_US
dc.rightsopen accessen_US
dc.subjectPartial discharge, HVDCen_US
dc.titleInvestigation of the effects of humidity and surface charge on partial discharge in insulator posts under DC voltageen_US
dc.typemaster thesisen_US
local.subject.manitobayesen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Deng_Hao_Liang.pdf
Size:
11.1 MB
Format:
Adobe Portable Document Format
Description:
Main article
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.2 KB
Format:
Item-specific license agreed to upon submission
Description: