Failure tests on full-scale models of grout laminated wood decks

dc.contributor.authorMufti, AA
dc.contributor.authorBakht, B
dc.contributor.authorSvecova, D
dc.contributor.authorLimaye, V
dc.date.accessioned2007-10-05T12:10:38Z
dc.date.available2007-10-05T12:10:38Z
dc.date.issued2004-01-31
dc.description.abstractGrout laminated wood decks (GLWDs), representing the third generation of stressed wood decks, comprise either laminates or logs trimmed to obtain two parallel faces. The logs or laminates, running along the span, are held together by means of transverse internal grout cylinders that may be in either compression or tension. Two full-scale models of GLWD were constructed at Dalhousie University, Halifax, one with grout cylinders in compression and the other with the cylinders in tension. Service load tests conducted in Halifax showed that the former deck had better load distribution characteristics. Two years after the tests in Halifax, the models were shipped to The University of Manitoba in Winnipeg, where they were tested to failure under a central patch load. Because of miscommunication with the supplier, the logs of the GLWD with grout cylinders in compression were also trimmed to the third face that was kept at the bottom of the deck. The failure tests showed that despite its superior load distribution characteristics, the deck with grout cylinders in compression failed at a significantly lower load than the GLWD with cylinders in tension. It is argued that a planar surface in the logs at the flexural tension face not only reduces their flexural stiffness but also brings the defects of wood to the surface with maximum stress. The deck with the flat bottom surface underwent tension failure of the most heavily loaded logs, whereas the deck with the intact round surface of the logs at both top and bottom failed by horizontal splitting of all the logs.en
dc.format.extent791770 bytes
dc.format.mimetypeapplication/pdf
dc.identifier.citation0315-1468; CAN J CIVIL ENG, JAN 2004, vol. 31, no. 1, p.133 to 145.en
dc.identifier.doihttp://dx.doi.org/10.1139/l03-088
dc.identifier.urihttp://hdl.handle.net/1993/2887
dc.language.isoengen_US
dc.rightsNo part of the NRC Research Press electronic journals may be reproduced, stored, or transmitted in any form or by any means, without the written permission of the publisher, except as stated below. Under the Canadian Copyright Act, individuals may download or print single copies of articles for personal research or study. Any person may reproduce short excerpts from articles in the journals for any purpose that respects the moral rights of authors, provided that the source is fully acknowledged. As a courtesy, the consent of authors of such material should be obtained directly from the author. Authorization to reproduce items for other than personal research or study, as stated above, may be obtained via Access © upon payment of the copyright fee of $10.00 per copy. NRC Research Press also extends certain additional rights to authors. The above rights do not extend to copying or reproduction for general distribution, for advertising or promotional purposes, for creating new collective works, or for resale. For such copying or reproduction, arrangements must be made with NRC Research Press.en
dc.rightsopen accessen_US
dc.statusPeer revieweden
dc.subjectarticulated plateen
dc.subjectbridge decken
dc.subjectgrout laminated decken
dc.subjectorthotropic plateen
dc.subjecttimberen
dc.titleFailure tests on full-scale models of grout laminated wood decksen
dc.typejournal articleen_US
Files